Abnormal handling

A runbook for the faults you'll actually hit. Each one: what the memo panel shows, what caused it, and what to do. Every scenario below is reproducible with the simulated MSense device — set the wristband's Fault column in Configuration → "MSense Demo (simulated)".

Watch it headlessly

plasma-ctl watch --fail-on L3 prints every colour change and exits non-zero the moment anything goes red — the building block for an unattended rig.


Wristband not found at Initialize

Memo: device not found

Memo device row red, device not found
Cause the wristband wasn't advertising / in range / paired when you pressed Initialize
Do check it's on and charged; re-scan under Configuration → "MSense wristbands" (before Initialize — single BLE radio); confirm the address in the table; Initialize again
Demo fault device_not_found

BLE drop mid-session

Memo: disconnected

Memo row amber, disconnected → then green, reconnected
Cause the link dropped (range, interference, a busy radio)
Do usually nothing — auto-reconnect brings it back within ~10 s and streaming resumes. The gap is in the recording; note it with a 🚩 journal flag. If it keeps dropping, move the base station closer.
Demo fault disconnect_reconnect

Memo: reconnected

…that doesn't come back

Memo row red, still disconnected (same message as the amber state — only the colour escalates once the recording's been silent ≈30 s)
Cause the link has stayed down through repeated reconnect attempts; the watchdog is still retrying every ~10 s but hasn't succeeded
Do the wristband is effectively out for now. 🎛️ Control → Advanced → 🔄 Reconnect now to force an attempt; if it won't come back, power-cycle the wristband and re-Initialize (this starts a new session folder). If it does reconnect, the row returns to green (reconnected).

SQC snapshot stalls

SQC tab: stalled

Where YAMS → 📡 Signal Quality status line; the wristband's memo row also goes amber
Memo / tab ❌ stalled (no notification for …s) — reconnected, press Request to retry
Cause the wristband's transmit buffer wedged mid-transfer; the no-progress watchdog stopped and reconnected it
Do press 📡 Snapshot all wristbands again. If it stalls repeatedly, switch Streaming mode to Sequential, or use Capture mode → History Only for a shorter transfer. A stalled snapshot does not affect a running session recording.
Demo fault sqc_error (snapshots), stream_stall (live streams)

Acquisition stop unconfirmed

Memo: stop unconfirmed

Memo row amber, still recording — stop unconfirmed
Where else YAMS → 🎛️ Control → Acquisition-stop confirmation lists it as unconfirmed · device may still be recording; the journal gets [ACQ] <name> stop UNCONFIRMED
Cause after Stop, PLASMA reads the wristband's acquisition flag back to confirm it actually halted (the Bluetooth ack alone doesn't prove it). It retried once and the flag still read "recording" — likely a firmware issue
Do the session's end boundary is uncertain — the wristband may have kept writing to its own flash past your Stop. Power-cycle the wristband before the next session. When you download its onboard data, expect extra tail samples after your intended stop time.
Demo fault acq_stop_ignored

Control tab: acquisition-stop confirmation

An unverifiable result () — older firmware whose flag isn't readable — is not a failure, just "couldn't check". A bare 🛑 on the memo row means the same.


Recorder unavailable

Symptom a toast: "LSL recording unavailable (liblsl/pylsl missing?)"; no .xdf is written; the memo's 📼 row is red
Cause liblsl isn't installed (see Install), or the recording file couldn't be opened
Do Stop is still safe — devices keep their own onboard recordings. Fix liblsl (conda install -c conda-forge liblsl), restart, and re-run. Don't rely on this session's XDF.

A recorded stream goes silent

Memo a green device row turns amber then red while its sample count stops climbing
Cause the device driver still thinks it's fine, but the LSL stream it publishes has gone stale (🟡) or lost (🔴)
Do check that device — cable, power, the app it depends on (OBS, Pupil, LiDAR). The memo caught it; the frozen sample count would not have.

Device fails to start

Memo row red, start failed — right after you pressed Start
Cause the device connected at Initialize but its start() threw (firmware state, a dependency not ready)
Do Stop, re-Initialize that device, Start again. Check the session log
(<home>/data/<date>_plasma_session.log) for the exception.

When to Restart vs Shut down

  • Restart (Configuration → Power) — after a demo-mode or catalog change, or when the app is in a weird state but you want to keep going. It reloads config from disk and flushes any running recording first.
  • Shut down — you're done. Clean exit, recording finalised.
  • Closing the browser tab or Ctrl-C also finalises a running recording (that wasn't always true — it is as of v2.x).

The paper trail

Every fault above is in two places you can read after the fact:

  • <home>/data/events.jsonl — machine-readable, one JSON line per change, survives restarts. plasma-ctl events --min-level L2 or tail -f. Schema: Files & paths.
  • <home>/data/<date>_plasma_session.log — the free-text session log; genuine failures are logged at WARNING / ERROR.